Mikrotron MC132x Especificações Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 45
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 10
Initial setup MC132x Users Manual Rev. 0.22
11
5 Initial setup
The MC132x is delivered with initial parameters and therefore does not need to be configured via the
serial link.
5.1 Serial number and firmware revision
Serial number and firmware revision is provided in MC132x non volatile memory. Use :v command
(Read serial number and firmware revision) to read serial number and firmware revision. The serial
number is also marked on the type plate of the camera.
5.2 PowerUpProfile
The PowerUpProfile is the contents of all camera registers to be loaded from non-volatile memory after
power up.
5.3 Camera Profile
The actual set of parameters is called Camera Profile. All changes of parameters by the serial link is
reflected in the Camera Profile. On command the Camera Profile is saved to 8 user profiles or one Pow-
erUpProfile. It is loaded from 8 user profiles or 8 factory profiles or the PowerUpProfile. The camera
profile is volatile and must be stored to the PowerUpProfile to be reactivated on next poer up.
5.4 Factory profile
The factory profile can be read but not written by the user. They are factory preset to the settings de-
scribed in the next chapter (user profiles).
5.5 User profiles
The user can store up to eight PowerUpProfiles in non volatile memory. All load or write commands
exchange data between the PowerUpProfile and one of the four user profiles.
Profil-Nr. Video data
width
/Mbyte/s
resolution
/ pixel
Image
frequency
/fps
0 48,5 100 x 100 4.852
1 58,2 240 x 240 1.011
2 62,1 640 x 480 202
3 61,6 1280 x 1024 47
4 48,5 100 x 100 4.852
5 58,2 240 x 240 1.011
6 62,1 640 x 480 202
7 61,6 1280 x 1024 47
Table 5-1